Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Laryngoscope ; 131(2): 448-452, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32562499

RESUMO

OBJECTIVES: Application of transcartilage needle electrode for intraoperative neuromonitoring (IONM) during thyroidectomy has been considered an alternative method of electromyography (EMG) tube recording. However, needle electrodes must be inserted into both sides of the thyroid cartilage with exposure of the cartilage lamina. We sought to evaluate the feasibility of applying a single ipsilateral transcartilage needle electrode for IONM during unilateral hemithyroidectomy. METHODS: Thirty-four patients underwent IONM during unilateral thyroidectomy. A dual disposable needle electrode was inserted obliquely into the inferior lower third of the ipsilateral lamina of the thyroid cartilage. Patients were classified as deep (≥ 5 mm) or superficial (< 5 mm) by the depth of the needle electrode inserted into the thyroid cartilage. Without using an EMG tube, IONM was done according to the standardized procedure using a single needle electrode only. RESULTS: IONM was successful in all nerves at risk. Amplitude of the EMG signal was stable during the surgery, with no cases presenting loss of signal. Amplitude of the signal from vagal and recurrent laryngeal nerve stimulation was significantly lower when needle insertion was superficial (< 5 mm). None of the patients showed postoperative vocal cord paralysis, and complications related to needle electrode were not identified. CONCLUSION: IONM using a single ipsilateral transcartilage needle electrode during unilateral hemithyroidectomy was feasible with no significant complications. It may serve as an alternative method of IONM with the advantage of minimal exposure of the thyroid cartilage lamina. LEVEL OF EVIDENCE: 4 Laryngoscope, 131:448-452, 2021.


Assuntos
Monitorização Neurofisiológica Intraoperatória/instrumentação , Complicações Pós-Operatórias/prevenção & controle , Cartilagem Tireóidea/cirurgia , Tireoidectomia/métodos , Paralisia das Pregas Vocais/prevenção & controle , Adulto , Idoso , Eletrodos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Monitorização Neurofisiológica Intraoperatória/métodos , Masculino , Pessoa de Meia-Idade , Agulhas , Complicações Pós-Operatórias/etiologia , Nervo Laríngeo Recorrente/cirurgia , Traumatismos do Nervo Laríngeo Recorrente/etiologia , Traumatismos do Nervo Laríngeo Recorrente/prevenção & controle , Cartilagem Tireóidea/inervação , Tireoidectomia/efeitos adversos , Resultado do Tratamento , Nervo Vago/cirurgia , Paralisia das Pregas Vocais/etiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...